Official Standard for powder: Indian Pharmacopoeia

official standard, powder

Coarse or fineness of powder is expressed by reference  to the nominal mesh aperture size of the sieve through which powder is able to pass.

Grade of powder as per Indian pharmacopoeia

1.            Coarse powder

2.            Moderately coarse powder

3.            Moderately fine powder

4.            Find powder

S. No.Grade of powderAll particles must pass through Sieve No. /Nominal mesh apertureSieve through which 40% of the particles pass/ Nominal mesh apertureComparison of powder size
1Coarse powder 10 /(1.70 mm)44 /(355 µm)1
2Moderately coarse powder22 /(710 µm)60/ (250 µm)1/6
3Moderately fine powder44/(355 µm)85/(180 µm)1/24
4Find powder85/(180 µm)Not specified1/90
Grade of powderIP

A) Coarse Powder:

  • A powder, all the particles of which pass through a sieve with nominal mesh aperture of 1.70 mm (Sieve No. 10 ) and not more than 40% pass through nominal mesh aperture of 355 µm (Sieve No. 44) is called a Coarse Powder.

B) Moderately Coarse Powder: 

  • A powder, all the particles of which pass through a sieve with nominal mesh aperture of 710 µm (Sieve No. 22) and not more than 40% pass through nominal mesh aperture of 250 µm (Sieve No. 60) is called a Moderately Coarse Powder.

C) Moderately Fine Powder:

  • A powder, all the particles of which pass through a sieve with nominal mesh aperture of 355 µm (Sieve No. 44) and not more than 40% pass through nominal mesh aperture of 180 µm (Sieve No. 85) is called a Moderately Fine Powder.

D) Fine Powder: 

  • A powder, all the particles of which pass through a sieve with nominal mesh aperture of 180 µm (Sieve No. 85) is called a Fine Powder.

E) Very Fine Powder:

  • A powder, all the particles of which pass through a sieve with nominal mesh aperture of 125 µm (Sieve No. 120) is called a Fine Powder.
  • Note:
    • For Fine & Very fine grade of powder: IP has prescribed only the upper limit (Fine & Very fine)
    • Fineness of powder is described by means of Number: it indicates that all particles of powder shall pass through that sieve number (respective nominal mesh aperture in µm).

Join Our WhatsApp Group to receive the latest updates like Pharma Job notifications, study materials, admission alerts, Pharma News, etc

Join Our Telegram Group to receive the latest updates like Pharma Job notifications, study materials, admission alerts, Pharma News, etc

Join Our Telegram Group to Download Free Books & Notes, Previous papers for D.Pharm, B.Pharm, M.Pharm, Drug Inspector & GPAT……….

Sign up to receive latest updates in your inbox.

Leave a Comment

Your email address will not be published. Required fields are marked *

Scroll to Top
Open chat
1
Need Help?
Welcome to The Pharmapedia
Hello,
How can we help you?